Scope of Energy Conservation in Pumping System

Authors

DOI:

https://doi.org/10.51611/iars.irj.v10i2.2020.105

Keywords:

Industrial Energy, Energy Conservation, Pumping System, Energy Efficiency

Abstract

Pumps consume about 22% of the world’s total energy generated, out of which 16% is consumed by centrifugal pumps and 6% by rotodynamic pumps. According to the American Hydraulics Institute, 30% of the total electrical energy consumed by pumping systems can be conserved either by designing highly efficient systems or by using appropriate pumps. As a result, the primary focus of global energy policy makers is to enhance energy efficiency in pumping systems. This paper aims to highlight the areas that need to be address in order to increase the pumping system efficiency. It is evident from studies that about 30% to 50% of the energy consumed by pumping systems could be saved through piping system components or control changes.

Downloads

Download data is not yet available.

References

U.S. Energy Information Administration. International energy outlook 2019

D Abdelaziz EA, Saidur R, Mekhilef S. ,”A review on energy saving strategies in industrial sector.” Renew Sustain Energy Rev 2011

Waide P, Brunner CU. Energy-efficiency policy opportunities for electric motor-driven systems international energy agency energy efficiency series; 2011.

European Commission. Study on improving the energy efficiency of pumps; 2001.

Tamminen J, Kosonen A, Ahonen T, Ahola J, Immonen P, Muetze A, et al. Component selection tool to maximize overall energy conversion efficiency in a pumping system. In: 2013 15th Eur. conf. power electron. appl. EPE 2013. IEEE; 2013, p. 1–9.

U.S. Department of Energy. Improving motor and drive system performance; 2008.

Kaya D, Yagmur EA, Yigit KS, Kilic FC, Eren AS, Celik C. Energy efficiency in pumps. Energy Convers Manage 2008;49:1662–73. http://dx.doi.org/ 10.1016/j.enconman.2007.11.010.

Lu S-M. A review of high-efficiency motors: specification, policy, and technology. Renew Sustain Energy Rev 2016;59:1–12. http://dx.doi.org/ 10.1016/j.rser.2015.12.360.

Aranto N. Competitor comparison: Variable speed drives in pumping applications; 2008.

B Stoffel. Assessing the Energy Efficiency of Pumps and Pump Units: Background and Methodology

Bureau of Energy Efficiency (BEE), India <https://beeindia.gov.in/>

Crossref Crossmark

Downloads

Published

2020-08-29

Issue

Section

Peer Reviewed Research Manuscript

How to Cite

“Scope of Energy Conservation in Pumping System” (2020) IARS’ International Research Journal, 10(2). doi:10.51611/iars.irj.v10i2.2020.105.

Citations

Similar Articles

1-10 of 37

You may also start an advanced similarity search for this article.